الخميس، 18 أبريل 2013

Radiographic view Comment




Radiographic view Comment



Mid and upper third Occipito-frontal (OF) 15-20 (Caldwell view) Used to visualize upper third of face
OF 25 (modified Caldwell view) Superior visualization of orbital floor relative to Caldwell view
Occipito-mental (OM) Used to visualize mid-third of the face
OM 10 Less obscuration of maxillary antrum than an OM view
OM 30 Superior view of malar arches and inferior orbital margins. Preferable
to submentovertical (SMV) view
Lateral Supplementary for central midface injury
Lower third Postero-anterior (PA) mandible
Lateral oblique Replaces OPG if not available or impractical
Reverse Townes Better visualizes mandibular condyles
Orthopantomogram (OPG)
INTRODUCTION
Maxillofacial imaging has evolved in parallel with the
development of newer imaging technologies. Traditional
plain radiography and dental imaging is now frequently
supplemented by cross-sectional modalities, such as
computed tomography (CT), magnetic resonance imaging
(MRI) and ultrasound, together with functional imaging
modalities, such as positron emission tomography (PET). It
is important to be aware of the benefits and limitations of
such imaging examinations such that they are applied to the
appropriate clinical scenario.
RADIATION PROTECTION
Some imaging investigations use ionizing radiation which
has the potential to result in biological damage. The aim of
radiation protection is to provide a safe environment for the
worker and patient. The Ionising Radiation (Medical
Exposure) Regulations 2000 (IRMER) lay down basic
measures required for protection against the harmful effects
of medical radiation exposure. There are duties of the
employer who provides a framework within exposures which
take place, the operator who carries out the exposure, the
practitioner who justifies the exposure and the referrer who
requests the exposure. Key principles are that the examination
should be of sufficient benefit to justify radiation exposure,
that dose is optimized by the ALARA (as low as is reasonably
achievable) principle and that dose limits should be recorded.
PLAIN RADIOGRAPHS
X-rays are produced by a point source and, after passing
through the body part of interest, are detected by non-screen (dental radiography) or intensifying screen/film
combinations (extraoral radiography). Selected facial
radiographic views are listed in Table 1.1.1. Tomography
refers to a technique whereby the x-ray source and film
move during the exposure. The aim is to demonstrate only
a section which is in focus, whereas structures outside this
section are blurred. Applications include conventional
dental panoramic tomography, tomograms of the
temporomandibular joints and mandibular tomograms for
implant planning.
1.1
Imaging techniques, including computed
tomography-guided biopsy and FDG-PET
STEPHEN E J CONNOR
Digital radiography units (using digital receptors to
intercept the x-ray beam rather than intensifying screens)
are now replacing conventional units. This allows
transmission of data to image processing and storage
devices, as well as communications networks.
CONTRAST STUDIES
Contrast media may be introduced into a vessel, lumen or
cavity in order to render it radio-opaque and hence
radiographically visible. This may then be viewed in real
time with fluoroscopic imaging or with serial radiographs.
Contrast media used for this purpose include barium
sulphate suspensions and non-ionic iodinated contrast
agents. There is a small risk associated with the intravascular
iodinated contrast agents which must be weighed against
the potential benefits. Information which should be sought
from the patient before contrast injection includes previous
contrast reactions, asthma, renal problems, diabetes and
metformin therapy.
Contrast studies with maxillofacial applications are:
1 Angiography: Conventional angiography is generally
performed as a precursor to interventional radiological
techniques. CT and MR angiography have largely
replaced diagnostic applications in maxillofacial
pathology. It remains appropriate for the planning of
embolization of high flow vascular malformations and
tumours (Figure 1.1.1) and for the evaluation of arterial
injury (traumatic or tumour erosion). Angiographic
catheters are generally introduced over a guidewire via a
common femoral artery puncture. Small calibre
microcatheters may be introduced into distal external
carotid artery branches.
2 Barium/contrast studies: Barium swallows may be
required to evaluate high dysphagia and pain. Rapid
serial radiography or video recording may be used to
assess the hypopharynx and upper oesophagus during
deglutition (Figure 1.1.2). Barium may be combined
with a gas-producing agent and an intravenous smooth
muscle relaxant to produce double-contrast images of
the lower oesophagus. If aspiration or tracheo-oesophageal fistulation is suspected, then a low osmolar
iodinated contrast medium will be used.
3 Sialogram: Iodinated contrast medium may be
introduced into the salivary duct ostium via a polythene
catheter. Fluoroscopy or radiography is used including
delayed images after administration of a sialagogue.
This is compared with preprocedure control films.
4 Sinogram/fistulogram: A sinogram involves the
insertion of a fine catheter into the orifice of a sinus and
injection of contrast medium in order to delineate a
sinus or fistula. If there is a complex tract then it may be
combined with CT.
5 Temporomandibular joint (TMJ) arthrogram :
Iodinated contrast medium is injected into the joint
under fluoroscopic guidance and double-contrast
studies may be achieved by contrast withdrawal and
replacement with air.
6 Dacrocystogram : The nasolacrimal sac and duct may
be cannulated and injected with contrast medium in
patients with epiphora. The lacrimal drainage system
may also be evaluated with CT and MRI following
conjunctival application of contrast medium.
7 Percutaneous venogram : Percutaneous venography may
be used as a precursor to sclerotherapy for the assessment
of volume and venous run off in the setting of low flow
venous malformations. A similar technique (lymphogram)
is used for a lymphatic malformation. Ultrasound is used
to guide the needle placement if the lesion is not clinically
palpable.
4 Imaging techniques, including computed tomography-guided biopsy and FDG-PET

التصوير الشعاعي وبالنظر إلى التعليق





ومنتصف الثلث الأعلى القذالي الجبهي (OF) 15-20 (عرض كالدويل) المستخدمة لتصور الثلث الأعلى من الوجه

25 (معدل كالدويل عرض) التصور فخمة من الدور المداري بالنسبة لعرض كالدويل

القذالي العقلية (OM) المستخدمة لتصور الثالثة منتصف الوجه

OM 10 أقل من التعمية غار الفك العلوي من وجهة نظر OM

OM 30 مشاهدة فخمة من الأقواس وجني وهوامش المدارية أدنى. أفضل

لsubmentovertical عرض (SMV)

التكميلية الجانبية للإصابة midface المركزية

خلفي-الأمامي السفلي الثالث (PA) الفك السفلي

ليحل محل منحرف الوحشي OPG إن لم تكن متاحة أو غير عملي

عكس تاونز أفضل يتصور اللقم الفك السفلي

Orthopantomogram (OPG)

مقدمة

وقد تطورت الوجه والفكين التصوير بالتوازي مع

تطوير تقنيات التصوير الحديثة. تقليدي

التصوير الشعاعي العادي والتصوير الأسنان هو الآن في كثير من الأحيان

تكملها طرائق مستعرضة، مثل

التصوير المقطعي (CT)، التصوير بالرنين المغناطيسي

(MRI) والموجات فوق الصوتية، جنبا إلى جنب مع التصوير الوظيفي

طرائق، مثل التصوير المقطعي بالإصدار البوزيتروني (PET). هذا

ومن المهم أن يكون على بينة من فوائد وقيود

الامتحانات التصوير مثل تلك التي يتم تطبيقها على

السيناريو السريرية المناسبة.

الحماية من الإشعاع

بعض التحقيقات التصوير استخدام الإشعاعات المؤينة التي

لديه القدرة أن ينجم عنه ضرر البيولوجية. والهدف من

الحماية من الإشعاع هو توفير بيئة آمنة لل

العامل والمريض. الإشعاع المؤين (الطبية

التعرض) لسنة 2000 (IRMER) وضع الأساسية

التدابير اللازمة لحماية ضد الآثار الضارة

التعرض للإشعاع الطبية. هناك واجبات لل

صاحب العمل الذي يوفر إطارا التعرض التي

تجري، المشغل الذي يقوم التعرض، على

الممارس الذي يبرر التعرض والمرجع الذي

تطلب إلى التعرض. المبادئ الأساسية هي أن الفحص

يجب أن تكون ذات فائدة كافية لتبرير التعرض للإشعاع،

أن جرعة هو الأمثل من قبل ALARA (منخفضة كما هو معقول

يجب تسجيل تحقيقه) ومبدأ أن حدود الجرعات.

الصور الشعاعية عادي

ويتم إنتاج الأشعة السينية من مصدر نقطة، وبعد مرور

من خلال جزء من الجسم من الفائدة، يتم الكشف عنها بواسطة غير شاشة (التصوير الشعاعي الأسنان) أو تكثيف الشاشة / الفيلم

تركيبات (التصوير الشعاعي خارج الفم). تحديد الوجه

يتم سرد المشاهدات إشعاعي في الجدول 1.1.1. الرسم السطحي

يشير إلى تقنية حيث مصدر الأشعة السينية وفيلم

تحرك خلال التعرض. والهدف هو إظهار فقط

وهو القسم الذي هو في التركيز، في حين أن الهياكل خارج هذا

غير واضحة القسم. وتشمل التطبيقات التقليدية

التصوير المقطعي بانورامية الأسنان، tomograms لل

المفاصل الصدغي والفك السفلي لtomograms

0 التعليقات:

إرسال تعليق

Twitter Delicious Facebook Digg Stumbleupon Favorites More

 
شقيق الروح